| SPECIFICATION Model HFO8 shall deliver a minimum of 8 GPH of water at 50°F water at 80°F inlet water at 90°F ambient (room temperature).Bubbler shall have flexible guard, lever handle and built-in pressure regulator to deliver smooth steady flow at supply pressures of 20 to 120 psi. Basin shall be designed to eliminate splashing and standing water. Cabinet finish shall be Dove Gray powder-coated paint on galvanized steel. Base shall be constructed of galvanized steel. Cooling system shall use R-134a refrigerant. Shall be Listed by Underwriters Laboratories, certified by Canadian Standard Association and conform to European Union Directives. Shall comply with ANSI/NSF 61 Model HFO8 delivers 8 gph of chilled drinking water. Standard Features - Waterways are lead-free in materials and construction - Dial-A-Drink Bubbler® with flexible guard - Stainless steel top - Heavy-gauge steel cabinet with separate galvanized steel base - High-efficiency cooling tank and coil - Refrigerant R-134a - Limited 5-year warranty Finishes - Dove Gray powder-coat paint Options (at additional charge) - Glass Filler (Factory Installed) Components in this water cooler are lead-free as defined by the Safe Drinking Water Act Amendments of 1986, and the Lead Contamination Control Act of 1988. Model HFO8 50°F Drinking Water 90°F Ambient Air Temperature Rating Condition 80°F inlet water temperature Rated Capacity GPH-8.0 Base Rate GPH-8.0 Pre-Cooler: Yes Hot’N Cold™ Model: No 115 Volts, 60 Hz Compr. HP: 1/6 Full Load Amps: 4.6 Rated Watts: 370 Glassfiller Acc. Option: Yes Net Wt Approx: 96 Lbs. Limited 5-Year Warranty: (Continental limits of the United Sates and Canada) Five-years on the sealed refrigeration system and most component parts. Detailed warranty certificate enclosed with each water cooler; sample copy available upon request. Export Warranty: One-year on sealed refrigeration system and most component parts. Four-year replacement contract on sealed refrigeration system. Detailed warranty certificate enclosed with each drinking fountain; sample copy available upon request. Models covered by this specification comply with all known Plumbing Codes. Listed by Underwriters’ Laboratories. Certified by Canadian Standards Association. |